1221 / 1231 Series Centrifuge Systems

The Ideal Aerosmith 1221 and 1231 Series of Centrifuge Systems are used to simulate G loads for inertial sensors, devices and components. These systems are designed for applications with larger payloads.

  • 1221 / 1231
  • 1221 / 1231
  • 1221 / 1231
Options available for

1221 / 1231

  • Additional slip ring lines
  • Wireless camera viewing system
  • Fluid transfer joint
  • Coaxial rotary joint
  • Positionable platforms (satellite tables)

Downloads

PDF files will open in browser upon download.
PDF 1221 Datasheet 144.2 kB - pdf DOWNLOAD
PDF 1231 Datasheet 135 kB - pdf DOWNLOAD

Standard Performance Specification & Features:

Standard Features Model 1221 Model 1231
G-range: 0 to 250 G’s (at 25 inch radius) 0 to 200 G’s (at 44 inch radius)
Payload Capacity: 18 in (45.7 cm) cube, 200 lbs (91 Kg) per arm 24 in (61 cm) cube, 200 lbs (91 Kg) per arm
Maximum G-lbs: 20,000 G-lbs.
Rate Range: 0-600 RPM 0-400 RPM
Test Load Radius: 15-33 inches (38.1-83.8 cm) 30-54 inches (76.2-137.2 cm)
Stability: ±0.1% of operating rate (above 60 rpm). Zero drift ±0.1% of operating rate (above 40 rpm). Zero drift
Controller: AERO 4000™ Digital Controller with centrifuge-specific GUI and advanced profile capabilities
Speed Indication Accuracy (includes meter and encoder error): 0.01% ±0.02 RPM 0.01% ±0.02 RPM
Slip Rings: Standard: 54 lines at 2A per line, 10 lines at 5A per line (other sizes available)
Other standard features: Unbalance sensor provides automatic shutdown in event of unbalanced loads; Electrical door interlocks prevent access inside enclosure while centrifuge is in motion; leveling kit; dynamic braking;