1068-1 / 1068-2 Series Centrifuge Systems

The 1068-1 and 1068-2 Series of Centrifuge Systems are used to simulate G loads for inertial sensors, devices and components.

  • 1068-1 & 1068-2
  • 1068-1 & 1068-2
  • 1068-1 & 1068-2
Options available for

1068-1 / 1068-2

  • Additional slip ring lines
  • IEEE-488 Communication Interface (replaces RS-232)
  • Wireless camera viewing system
  • Fluid transfer joint
  • Coaxial rotary joint
  • Larger arms
  • Positionable platforms (satellite tables)

  Almost every system that Ideal Aerosmith manufactures is customized for our customer. The above specifications should be used for reference only.

Downloads

PDF files will open in browser upon download.
PDF 1068-1 Datasheet 120.5 kB - pdf DOWNLOAD
PDF 1068-2 Datasheet 91.5 kB - pdf DOWNLOAD

Standard Performance Specification & Features:

Standard Features Model 1068-1 Model 1068-2
G-range: 0 to 100 G’s (at 22 inch radius) 0 to 1000 G’s (at 10.5 inch radius)
Payload Capacity: 12 in (30.5 cm) cube, 50 lbs (22.7 Kg) per arm 24 in (61 cm) tabletop, 50 lbs (22.7 Kg)
Maximum G-lbs: 5000 G-lbs.
Rate Range: 0-400 RPM 0-1900 RPM
Radius: 15-27 inches (38.1-68.6 cm) tabletop area to 12 inches (30.5 cm)
Stability: ±0.1% of operating rate (40-400 rpm). Zero drift ±0.1% of operating rate (190-1900 rpm). Zero drift
Controller: Digital, closed-loop with keypad interface and RS-232 interface
Display: Digital readout, XXXX.X Digital readout, XXX.XX
Speed Indication Accuracy (includes meter and encoder error): 0.01% ±0.02 RPM 0.01% ±0.1 RPM
Axis Rate Accuracy: ± 0.1% (40-400 RPM) ± 0.1% (190-1900 RPM)
Vibration Isolation: Less than 0.1 G from DC to 100 Hz
Slip Rings: Standard: 8 lines at 5A per line (other sizes available)
Other standard features: Unbalance sensor provides automatic shutdown in event of unbalanced loads; Electrical door interlocks prevent access inside enclosure while centrifuge is in motion; leveling kit; dynamic braking; over-under speed indicator; 6000 pulse per rev encoder